A single-point strategy based on IEEE 1459-2000 for the Detection of Dominant Harmonic Sources in Power Systems
2008
This paper deals with a novel single-point strategy for the detection of harmonic sources in power systems. It is an enhancement of a previous strategy, developed by authors, which is based on the IEEE Std. 1459-2000 approach. In the paper, the effectiveness of the strategy is investigated, by means of simulation tests, which were carried out on a IEEE standard three-phase test power system. The analysis is carried out by considering also the presence of the measurement transducers.
Disturbing Load Detection in Three-Wire and Four-Wire Systems Based on Novel Nonactive Powers From IEEE 1459-2000
2010
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems, both three-wire and four-wire. It is based on the IEEE Std. 1459-2000 effective apparent power resolution, and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In this paper, the formulation of the novel approach is given, and its effectiveness is discussed by means of several simulation tests, which were carried out on a simple test system.
A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000
2010
In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…
Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010
2020
The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …
Polluting loads detection in power systems: a decision-making strategy based on nonactive power measurements
2010
In this paper a novel decision-making strategy is proposed for the detection of polluting loads in three-phase power systems. It makes use of simple indices, which are expressed as a function of some nonactive power quantities, previously proposed by the authors and derived from the approach of the IEEE Std. 1459–2000. The decision-making rules for the proposed strategy are presented and discussed, by means of some simulation tests.
A novel approach based on nonactive powers for the identification of disturbing loads in power systems
2007
In this paper, a new approach is proposed for the detection of harmonic sources in polluted power systems. It is a single- point strategy, based on a comparison among different "nonactive" power quantities proposed in literature that, in the same working conditions, assume different values at the same metering section. Some simulations tests were carried out on a standard IEEE test system proposed by other authors as a benchmark system for the analysis of multipoint measurement techniques for harmonic pollution monitoring. The obtained results show that the proposed single-point approach is in agreement with other strategies already proposed in the literature and can provide useful indicati…
Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers
2007
This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers.
Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems
2008
This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…
An enhanced approach based on IEEE 1459 for the detection of disturbing loads in distorted and unbalanced three-phase power systems
2009
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems in both cases of three and four-wires. It is based on the IEEE Std. 1459-2000 effective apparent power resolution and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In the paper, the formulation of the novel approach is given and some simulation results are presented.
IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment
2018
The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.